Great Power has successfully completed a full-scale fire test with its Max-20HC-5000 DC liquid-cooling container battery energy storage solution, which features 314 Ah LFP battery cells and has a rated energy capacity of 5 MWh.
The test focused on the system-level fire safety performance of Great Power’s system and was conducted with reference to ANSI/CAN/UL 9540A:2026.

Full-Scale Fire Test Overview
The test was designed to simulate a worst-case field failure scenario: the battery system was charged to 100% State of Charge (SOC), the container doors were closed, and the active fire suppression system was manually disabled. Thermal runaway and fire were intentionally triggered in one of the battery modules.
- Fourteen cameras were deployed—seven inside the burning container and seven outside—to continuously record the impact of flames and heat on surrounding equipment and building structures.
- A highly challenging installation spacing was adopted: the minimum gap between the two containers was only **150 mm**; the burning container faced another energy storage unit, and a test wall was positioned 3,000 mm away from the electrical compartment.
- Cell temperatures inside the adjacent container were monitored throughout the test to verify whether thermal isolation and heat dissipation paths could prevent the spread of the hazard.
Flame propagation, the occurrence of secondary thermal runaway, and the structural integrity of the container were observed throughout the test. Monitoring continued after ignition until the fire subsided;
the fire **extinguished itself after 16 hours**, and a test certificate was ultimately issued by TÜV Rheinland.
Key Test Results

The battery test from Cell to the whole installation for the fire suppression test.
What does this fire test mean for energy storage projects?

Great Power’s Expertise in Energy Storage Safety
According to Frost & Sullivan, Great Power ranked No. 1 globally in residential energy storage battery shipments in H1 2026, with a 28% market share.
In recent years, the company has expanded its scope to produce not only LFP batteries, but also solid-state and sodium-ion batteries for applications from homes to AI data centers.
Great Power’s energy storage cell manufacturing is over 95% automated to ensure consistency and reliability, with flexible packaging and integration lines to enable customized solutions for its customers.
In 2025, the company obtained the EN 9100:2018 Aerospace and Defense Quality Management System Certification from TÜV Rheinland Greater China for its Zhuhai manufacturing base,
confirming that the company’s quality management system meets the requirements of EN 9100:2018 and is registered in the IAQG OASIS database.
Summary
The successful full-scale fire test marks another milestone for Great Power’s liquid cooled container BESS.
As energy storage safety requirements continue to tighten globally, full-scale fire testing will become a key benchmark for selecting reliable container energy storage solutions.
Backed by Great Power’s high automation battery manufacturing capacity, diversified product portfolio covering residential, commercial/ industrial and data-center-grade storage solutions, and authoritative quality certifications such as EN 9100:2018, this fire-test milestone reinforces the competitiveness of Great Power’s liquid-cooled container BESS amid tightening global energy storage safety standards.
Custom engineered safe battery container solutions are available for client-specific project requirements.
If clients has customized battery container inquiry, we welcome clients contact us to have a customized safe solar container solution.
Leave A Message
Scan to Wechat :
Scan to WhatsApp :